Both-OpenTransformers are one of the most expensive and critical assets in the electrical grid. So preventing problems or failures is vital to maintaining a safe, reliable and financially sound operation. One of the best ways to safe guard this investment is to follow the transformer manufacturer’s recommendation to regularly draw oil and gas samples to conduct laboratory testing and analyses. Diligently following this recommendation has proven to be a reliable method for increasing asset longevity by predicting potential problems and applying interventional maintenance before it occurs. Historically, the transformer manufacturers have installed oil and gas sampling devices and gauges inside the transformer enclosure compartment. However, with the increased awareness of arc flash dangers and changes in the NFPA 70E standards, the need for unwanted and costly power outages may be necessary to gather the samples.

Therefore, to provide a solution that optimizes safety and reliability, Heartland Solutions, Inc., a leader in Transformer Condition Monitors (TCMs), proudly introduces the new External Oil and Gas Sampling TCMTM (Standard Module) and the External Oil Fill and Conditioning TCMTM (Expanded Module). These multi-functional TCM’s are fully-integrated systems conveniently mounted on the exterior of the transformer cabinet to allow oil and gas sampling along with fill and conditioning operations. The TCMs include the following functions:

Function Modules
Standard Expanded
Gas Pressure/Vacuum Indication X
Gas Over Pressure Indication X
Gas Sampling X
Gas Filling X
Gas Purging X
Gas Pressure/Vacuum Regulation Bleeder X
Oil Sampling X
Oil Draining X
Oil Filling X
Oil Conditioning X

What’s in the rugged NEMA box?

CloseupHeartland uses in every module only Heartland TCM products, which are designed to meet or exceed ANSI and industry standards. Moreover, these Heartland TCMs are approved by the major worldwide transformer OEMs and have been installed in the low voltage compartment of the transformer for decades. Remarkably, many of the same transformers are now candidates to be retrofitted with the Heartland External Oil and Gas Sampling TCMTM (Standard Module) and the External Oil Fill and Conditioning TCMTM (Expanded Module) – and are more economical alternatives to the expensive on-line monitor solutions on the market today.
 


 
To discuss your specific application requirements or to order any of these six (6) Standard Modules configurations and/or one (1) Expanded Module, please contact us at +1.815.855.5000 or Toll-Free in the U.S and Canada at 1.800.957.3493.

Heartland Solutions, Inc. manufacturers an extensive line of Transformer Condition Monitors (TCMs) designed to monitor the temperature, fluid and gas in new and existing T&D transformers and other electrical equipment.